Produtos

Produtos

Anhui Liwei Chemical Co., Limited.

Copolímero DA-1133 VAE RDP

    • Nome do produto: Copolímero DA-1133 VAE RDP
    • Site da Factroy: Lingwu, Yinchuan, Ningxia, China
    • Consulta de preço: sales2@liwei-chem.com
    • Fabricante: Anhui Liwei Chemical Co., Limited.
    • Contacte Agora
    Especificações
    Código SH 187246
    Nome Do Produto Copolímero DA-1133 VAE RDP
    Composição Química Copolímero de acetato de vinila-etileno
    Forma Física Pó branco
    Densidade Aparente 400-600 g /L
    Tamanho Médio Das Partículas 80 µm
    Conteúdo Sólido ≥ 99%
    Teor De Cinzas ≤ 15%
    Colóide Protetor álcool polivinílico
    Agente Antiaglomerante Agente mineral antiaglomerante
    Temperatura Mínima De Formação De Filme Mfft 5 ° C
    Temperatura De Transição Vítrea Tg 0 ° C
    Ph Em Dispersão 5,0-7,0
    Redispersibilidade Excelente em água
    Estabilidade De Armazenamento 12 meses em condições secas

    Como fábrica credenciada Copolímero DA-1133 VAE RDP, aplicamos protocolos de qualidade rigorosos - cada lote é submetido a testes rigorosos para garantir padrões de eficácia e segurança consistentes.

    Embalagem e armazenamento
    Embalagem DA-1133 VAE Copolymer RDP é embalado em sacos kraft multicamadas de 25 kg com forros de polietileno, paletizados e embalados em retrátil para proteção.
    Carga de contêiner (20' FCL) FCL de vinte pés, paletizado e estirado, protegido contra umidade, empilhamento estável para o copolímero RDP DA-1133 VAE.
    Envio DA-1133 VAE Copolymer RDP é fornecido em sacos multicamadas à prova de umidade, normalmente 20 kg cada. Proteja da água, umidade e luz solar direta durante o transporte. Armazene em uma área fria, seca e ventilada. Evite compactação, empilhamento danos e exposição prolongada ao calor. Manuseie com cuidado para preservar a integridade do produto.
    Armazenamento Armazene o copolímero RDP DA-1133 VAE em uma área fria, seca e bem ventilada, longe da luz solar direta e das fontes de calor. Mantenha a embalagem original selada e sele novamente após o uso para evitar a absorção de umidade. Armazene em paletes em recipientes originais, idealmente a 5 35 ° C, e use dentro de sua vida útil designada para manter o desempenho.
    Prazo de validade O prazo de validade é de 6 meses a partir da produção, quando armazenado fechado em local fresco e seco, evitando a umidade.
    Aplicação do Copolímero DA-1133 VAE RDP

    Ceramic tile adhesive dry-mix producers targeting a C2TE classification must decide whether a VAE copolymer redispersible polymer powder can replace a portion of the liquid polymer dispersion without reducing open time or increasing shear creep. DA-1133 is typically incorporated at 2.0–4.0 wt% of total dry-mix mass, with 3.0 wt% used as the primary screening dosage in formulations containing 32–40 wt% CEM I 42.5 R Portland cement, 0.3–0.5 wt% hydroxyethyl methyl cellulose ether having a solution viscosity of 20 000–40 000 mPa·s at 2% concentration, and graded silica sand with a 0.5 mm top size. On a production-scale twin-shaft paddle mixer operating at 30–45 rpm, the cement and sand are charged first, the cellulose ether is dispersed for 60–90 s, and DA-1133 is introduced only after the fine binder components have been distributed; reverse loading of low-bulk-density powder into an empty mixer creates side-wall accumulation and raises batch-to-batch tensile adhesion scatter, sometimes moving a borderline C2TE formula below the required threshold on retesting. The mixed powder is discharged through a 1.8–2.5 mm sieve and bagged only after residual moisture is confirmed below 0.3 wt%. The compliance framework for this segment is anchored to EN 12004-1:2017 for classification and EN 12004-2:2017 for test methods, with additional verification under ANSI A118.15 for large-format tile adhesives. The terminal finished products include C2TE thin-bed adhesives for large-format porcelain panels, swimming pool tile adhesives with continuous water exposure, and adhesives specified for underfloor heating assemblies where thermal cycling resistance is a design requirement. The operational boundary is clear: adding DA-1133 above 4.5 wt% is not generally recommended because the increased polymer film content can reduce early compressive strength and raise permanent creep under sustained load.

    Required performance verification for C2TE tile adhesive formulations containing DA-1133
    Verification parameterStandard designationTest clause /methodC2TE requirement
    Tensile adhesion dryEN 12004-1:2017EN 12004-2:2017, 6.1≥ 1.0 N/mm²
    Tensile adhesion after water immersionEN 12004-1:2017EN 12004-2:2017, 6.2≥ 1.0 N/mm²
    Tensile adhesion after heat ageingEN 12004-1:2017EN 12004-2:2017, 6.3≥ 1.0 N/mm²
    Tensile adhesion after freeze-thawEN 12004-1:2017EN 12004-2:2017, 6.4≥ 1.0 N/mm²
    Vertical slipANSI A118.15Slip resistance method≤ 0.5 mm

    What happens to self-leveling underlayment flow retention when DA-1133 is introduced at 2.5 wt%?

    In self-leveling underlayments, the addition of DA-1133 at 2.5 wt% dry-mix basis alters the relationship between low-shear viscosity and high-shear flow, and this segment is controlled by rheological acceptance rather than adhesive bond values. For one-component floor screeds based on calcium aluminate cement or a combined Portland cement and calcium sulfate system, the practical addition range is 1.5–3.0 wt%, with the exact dosage adjusted to maintain a flow cone spread of 140–160 mm under EN 12706. The downstream production process frequently uses a high-intensity ploughshare mixer running at 1500–3000 rpm for a short 60–120 s cycle; this is necessary to distribute the redispersible polymer powder without overheating the gypsum component above 45°C, which could trigger premature anhydrite rehydration and produce lump formation. The mixed underlayment is applied by pump and smoothing roller, and the most common field defect is pinhole formation caused by entrapped air that VAE powder can stabilize when no dry defoamer based on mineral oil or polyglycol is included. Compliance in this segment is driven by EN 13813 for cementitious screed materials and ASTM C1708/C1708M-21 for self-leveling mortars; commonly specified classes include CT-C25-F6 or CT-C30-F7, corresponding to compressive strengths of 25–30 N/mm² and flexural strengths of 6–7 N/mm² at 28 days. Terminal products include self-leveling underlayments for vinyl and LVT flooring, industrial floor repair compounds, and acoustic screeds where a lower dynamic modulus is needed. The critical limit in this segment is water demand: DA-1133 increases viscosity and water retention, so total mixing water is typically held at 20–25 wt%, and deviation above 25 wt% can generate bleeding, surface softness, and delayed setting.

    At the interface between an expanded polystyrene insulation panel and a glass-fibre mesh-reinforced base coat, the redispersible polymer film is the dominant variable controlling impact resistance and crack control after freeze-thaw exposure. DA-1133 is dosed at 2.5–4.0 wt% of dry base coat mass, with formulations typically containing 25–30 wt% white Portland cement, 1.0–2.0 wt% cellulose ether, and 0.5–1.0 wt% hydrophobic additive based on calcium stearate or organosilane. The dry-mix production line uses a horizontal ribbon blender with a fill ratio not exceeding 70%; the hydrophobic additive must be added after DA-1133 to prevent segregation of the low-density powder on the ribbon shaft. The base coat is applied by trowel or spray machine in a 3–5 mm layer onto expanded polystyrene boards having a minimum density of 15–20 kg/m³, and the glass-fibre mesh is embedded while the surface is still wet. The compliance reference for this segment is ETAG 004 /EAD 040083-00-0404, with additional requirements from EN 13499 and EN 13914-2:2016 for rendering application. Impact resistance measured by a 3 J impact on the hardened base coat must be sufficient to prevent cracking that exposes the insulation board; the addition of DA-1133 alone does not guarantee impact resistance, and excessive polymer content above 4.0 wt% can reduce compressive strength below the value required for load transfer through the adhesive layer. Terminal finished products include ETICS base coats over EPS and mineral wool, adhesive mortars for thermal insulation boards, and one-part renovation dressings over existing rendered facades. The operational boundary is that film coalescence below 5°C is incomplete, and application at relative humidity below 40% may lead to premature drying and mesh adhesion loss.

    When gypsum-based skim compounds need moisture resistance without losing sandability

    Gypsum joint fillers and skim compounds containing DA-1133 present a formulation contradiction: the polymer film reduces surface absorption and improves adhesion to gypsum board, but also raises surface hardness, which can reduce sandability and increase edge burnishing during mechanical finishing. In this segment, DA-1133 is used at the low end, typically 0.5–2.0 wt% of total mix mass, with 1.0 wt% as the starting point for hand-applied products and 1.5–2.0 wt% for machine-applied skim coats requiring better build-up. The downstream dry-mix process combines beta-hemihydrate gypsum, calcium carbonate fines with a median particle size of 10–20 µm, and DA-1133 in a ribbon mixer at 50–70 rpm for 120–180 s; the powder is then site-mixed with water for 2–3 min, allowed to slake for 60 s, and applied by trowel or airless spray in layers of 1–3 mm. The governing compliance standards are EN 13963:2014 for joint fillers and ASTM C475/C475M-21 for joint compound and patching compound; additionally, sanding hardness and surface absorption are evaluated against the contract specification rather than a single EN requirement. Terminal product types include drywall joint compounds, gypsum repair fillers, painted-surface patching compounds, and machine-applied gypsum skim coats for residential renovation. The limitation in this segment is that DA-1133 does not function as a set retarder; when the addition exceeds 2.0 wt%, the calcium sulfate hydration may be masked by the polymer film and the surface may feel dry before the core has fully set, producing sanding defects and localized delamination under subsequent paint layers.

    Balcony membranes in wet-room ceramic tile installations require a crack-bridging waterproofing layer whose low-temperature flexibility does not come from migrating external plasticizers. DA-1133 is incorporated at 3.0–6.0 wt% of the dry-mix mass in one-component flexible cementitious slurries, with higher dosages within that range reserved for membranes specified to bridge cracks of 0.75 mm under EN 14891:2017. The dry component consists of Portland cement, graded silica sand, and DA-1133; on site it is mixed with water in a low-shear drill at 400–600 rpm for 2 min, left to stand for 5 min, and applied by brush, roller, or notched trowel in two to three coats to a total wet thickness of 1.5–2.0 mm. The key production bottleneck is not mixing but recoating time: at 23°C and 50% relative humidity, the first coat must be sufficiently dry to support the second coat, typically after 4–6 h; application at lower temperatures extends this to 8–12 h and may delay membrane setting. The governing compliance standard is EN 14891:2017 for liquid-applied water impermeable products beneath ceramic tiling; a cementitious slurry formulated with DA-1133 in this range can be evaluated against class CM01P for crack bridging and class CM02P for water impermeability. Terminal products include balcony and terrace membranes, wet-room tanking slurries, swimming pool shell waterproofing, and external water tank linings. The limitation is continuous water immersion: the membrane should not be considered fully cured until 7 days at 20–23°C, and early ponding may cause efflorescence, surface softening, or reduced adhesion to the subsequent tile adhesive.

    Repair mortar modulus and thermal expansion when a VAE copolymer film redisperses in low-water-cement mixes

    The decision to add DA-1133 to a structural repair mortar is not governed by tensile adhesion alone but by the need to lower elastic modulus and reduce shrinkage cracking without lowering compressive strength below the required class. In this segment, DA-1133 is typically added at 1.5–3.0 wt% of total dry mass, with 2.0 wt% used in polymer-modified R3 repair mortars and the lower end of the range used in R4 formulations where compressive strength must exceed 45 N/mm² at 28 days under EN 12190. The downstream production process differs from tile adhesives because the aggregate packing is coarser, often up to 4 mm, and the dry-mix plant must use a forced-action mixer with sufficient shear to distribute DA-1133 onto both fine and coarse particles; dust generation is controlled by adding the powder through a gravity feeder after the coarse aggregate has been pre-wetted by a small amount of water or plasticizer. The hardened material must satisfy EN 1504-3 for structural repair, with additional shear bond verification under EN 12615 and shrinkage measurement under EN 12617-4; the presence of DA-1133 can reduce modulus toward the lower bound for R3-type products, which improves crack accommodation but may increase creep under continuous dead load by a measurable amount. Terminal finished products include hand-applied spall repair mortars, vertical edge repair mortars, column restoration mortars, and low-shrinkage patch compounds for structural and non-structural concrete repairs. The critical limitation is that DA-1133 is not a substitute for proper substrate preparation: if the concrete substrate is not saturated surface-dry and free of laitance, the polymer film will not compensate for bond failure at the interface, and the repair may fail in shear or blister under thermal movement.

    Cotação Grátis

    Preços competitivos do Copolímero DA-1133 VAE RDP que se ajustam ao seu orçamento - termos flexíveis e orçamentos personalizados para cada pedido.

    Para amostras, preços ou mais informações, entre em contato conosco em +8615380400285 Ou envie para sales2@liwei-chem.com.

    Responderemos a você o mais rápido possível.

    Telefone: +8615380400285

    E-mail: sales2@liwei-chem.com

    Inquérito

    Obtenha um orçamento gratuitoAnhui Liwei Chemical Co., Limited.

    Pagamento flexível, preço competitivo, serviço premium - Consulte-nos agora!

    Certificação e Conformidade
    Mais Introdução
    O copolímero DA-1133 VAE RDP é um pó de polímero redispersível em água fabricado por secagem por pulverização de uma dispersão de copolímero acetato de vinilo-etileno estabilizada com um colóide protetor de álcool polivinil. O produto é fornecido como um pó de fluxo livre branco a branco e é destinado a argamassa de mistura seca a base de cimento e gesso. Em uma formulação padrão rica em cimento, o pó é adicionado em 1,5% em peso a 5,0% em peso de ligante seco e redisperse durante a mistura úmida para formar uma matriz modificada por polímero. O conteúdo médio de etileno do copolímero base coloca a temperatura de transição vítrea perto de 0 °C, o que fornece um equilíbrio entre flexibilidade e resistência à tração na argamassa curada.