Fibra Kuraray RF4000-PVA para reforço de concreto

    • Nome do produto: Fibra Kuraray RF4000-PVA para reforço de concreto
    • Site da Factroy: Lingwu, Yinchuan, Ningxia, China
    • Consulta de preço: sales2@liwei-chem.com
    • Fabricante: Anhui Liwei Chemical Co., Limited.
    • Contacte Agora
    Especificações
    Código SH 663146
    Nome Do Produto Fibra Kuraray RF4000-PVA para reforço de concreto
    Material Álcool polivinílico (PVA)
    Fibra Forma Microfibra monofilamento
    Comprimento 6 milímetros
    Diâmetro 27 milímetros
    Gravidade Específica 1,30
    Resistência à Tracção 1100 MPa
    Módulo De Elasticidade 29 GPa
    Alongamento Na Ruptura 7%
    Ponto De Fusão 230 ° C
    Resistência Alcalina Excelente
    Dispersibilidade No Concreto Bom
    Cementitious Ligação Forte, devido à superfície hidrofílica

    Como fábrica acreditada Fibra Kuraray RF4000-PVA para reforço de concreto, aplicamos protocolos de qualidade rigorosos - cada lote é submetido a testes rigorosos para garantir padrões de eficácia e segurança consistentes.

    Embalagem e armazenamento
    Embalagem As fibras Kuraray RF4000-PVA são fornecidas em sacos solúveis em água de 1 kg, dissolvidos em concreto, com 20 sacos por caixa.
    Carga de contêiner (20' FCL) 20 "FCL: Fibras Kuraray RF4000 PVA embaladas em caixas /paletes, carregadas com segurança, protegidas da umidade, prontas para o transporte de contêineres.
    Envio A fibra Kuraray RF4000-PVA é enviada em sacos ou caixas selados e resistentes à umidade em paletes, protegidos contra umidade excessiva. O frete padrão via caminhão ou contêiner é adequado. Nenhuma designação especial de materiais perigosos se aplica em condições normais de seca. Mantenha longe de fontes de ignição e armazene em uma área fria e seca durante o trânsito.
    Armazenamento Armazene em uma área fria, seca e sombreada em embalagem original fechada. Mantenha longe de umidade, chuva e luz solar direta para evitar aglomeração ou degradação. Mantenha a temperatura moderada e gire o estoque usando um sistema de entrada e saída. Com o armazenamento selado adequado, a vida útil é normalmente longa, mas evite a exposição prolongada à alta umidade.
    Prazo de validade Prazo de validade: Indefinido quando armazenado na embalagem original em uma área seca e fria, longe da luz solar direta e da umidade.
    Aplicação de Fibra Kuraray RF4000-PVA para reforço de concreto
    Os segmentos de revestimento de túnel de concreto armado pré-fabricado produzidos com RF4000 são qualificados de acordo com as disposições de fibra de polímero de classe II para concreto estrutural e ASTM C1116/C1116M Tipo III de concreto armado com fibra sintética, enquanto a tolerância dimensional e a verificação da carga seguem as regras comuns para concreto pré-fabricado de acordo com a EN 13369:2023. A fibra é introduzida a 2,4–3,8 kg/m³, correspondente a 0,18–0,29% vol a uma gravidade específica nominal de 1,30 g/cm³, em um misturador de contracorrente de dois eixos com uma capacidade nominal de lote de 1,5 m³. O ponto de adição é movido para a corrente de agregado misturado após a adição de 60-70% de água em lote, porque a descarga direta sobre superfícies secas de agregado foi observada em linhas de carrusel para produzir aglomeração de fibras nas placas de desgaste do misturador. Uma alimentação em etapas de 0,25–0,5 kg/s através de uma unidade de dosagem vibratória é mantida em vez de esvaziar um saco completo de 20 kg, e o misturador é executado a 25–35 rpm por 60–90 s após a introdução da fibra. O concreto fresco é ajustado a uma queda de 40-70 mm com um redutor de água de alta gama de policarboxilato-éter em 0,8-1,2% em peso do ligante cimentário, porque a adição RF4000 pode aumentar a perda de queda precoce em 30-50 mm ao longo de 45 min a 25 °C. Os moldes de segmento são preenchidos através de tolvas laterales e compactados em vibradores externos de alta frequência que operam a 50-60 Hz; a fibra não altera materialmente o tempo de compactação, mas pode aumentar o desenfuzimento da superfície se o molde for excessivamente vibrado além de 90 s por derramamento. A cura a vapor é tapada a 60 °C para permanecer dentro da janela de temperatura de serviço prolongada da fibra, com um ciclo total de 6-8 h antes do desmoldamento. Os produtos terminais são aneis segmentais com vedação parafusada para túneis movidos por escudos com diâmetros internos de 4 m a 12 m, espessuras típicas de 200-350 mm, e requisitos de vida útil de 100 anos sob as classes de exposição XC3 e XD1 da EN 1992-1-1:2004. RF4000 é empregado como reforço secundário de controle de rachaduras e não substitui o reforço de aço convencional em zonas de tração de aro; Os dados publicados sobre a distribuição de fibras a nível de segmento na produção em escala completa permanecem limitados, por isso são necessários ensaios pré-produção em condições reais da planta.

    Cotação Grátis

    Preços competitivos Fibra Kuraray RF4000-PVA para reforço de concreto que se ajustam ao seu orçamento - termos flexíveis e orçamentos personalizados para cada encomenda.

    Para amostras, preços ou mais informações, entre em contato conosco em +8615380400285 Ou envie para sales2@liwei-chem.com.

    Responderemos a você o mais rápido possível.

    Telefone: +8615380400285

    E-mail: sales2@liwei-chem.com

    Inquérito

    Obtenha um orçamento gratuitoAnhui Liwei Chemical Co., Limited.

    Pagamento flexível, preço competitivo, serviço premium - Consulte-nos agora!

    Certificação e Conformidade
    Mais Introdução

    Kuraray RF4000-PVA fiber is a monofilament polyvinyl alcohol macrofiber supplied for reinforcement of hydraulic cementitious matrices. Published technical data for the product list a nominal cut length of 40 mm, an equivalent filament diameter of 0.66 mm, a nominal aspect ratio of 61, and a polymer density of 1.30 g/cm³. The fiber is reported with a tensile strength of 1000 MPa, an elastic modulus of 30 GPa, and an elongation at break of 7%. These values are geometry-dependent and should be verified against the manufacturer’s current batch certificate prior to mix design. The material is classed as a macrofiber because its equivalent diameter exceeds 0.3 mm; it is intended for concrete, mortar, and dry-process shotcrete. Compliance in the European Economic Area is assessed under EN 14889-2:2006, which specifies definitions, specifications, and conformity procedures for polymer fibres used in concrete. In North American practice, fiber-reinforced concrete containing PVA macrofiber is evaluated under ASTM C1116/C1116M-23 for classification and under ASTM C1609/C1609M-24 for flexural performance.

    Unlike polypropylene, the polyvinyl alcohol backbone carries pendant hydroxyl groups that render the fiber hydrophilic. This surface chemistry modifies the fiber-cement transition zone; interfacial bond is developed by a combination of adhesion, friction, and potential chemical interaction with calcium hydroxide. The fiber is stable in saturated calcium hydroxide solution at pH values above 12.5, which distinguishes it from E-glass fibers that degrade in non-alkali-resistant grades.

    What Limits Fiber Dispersion in High-Shear Concrete Mixing?

    In batching operations, RF4000-PVA fiber is introduced through aggregate preblending or through fiber dispensing equipment after coarse aggregate charging. The primary processing constraint is the combination of 40 mm cut length and 61 aspect ratio, which can produce interlocking and agglomeration in low-shear truck mixers or free-fall mixers. In compulsory twin-shaft mixers with batch capacities of 1.0–3.0 m³, dry fiber is generally added after the coarse aggregate and before the first water addition; aggregate attrition separates individual fibers. When fiber is added after water, cement paste adhesion to the wet fiber surface increases the probability of fiber balling within 60 seconds of wet mixing at dosages above approximately 2.0 kg/m³. A staged water addition sequence—60–70% of mix water before fiber and 30–40% after fiber—is applied in some precast plants to reduce this failure mode. After all fiber is charged, a wet mixing interval of 4–6 minutes at high shear is used; extending beyond 8 minutes can collapse entrained air and increase slump loss. In a 750 L planetary counter-current mixer with a pan speed of approximately 28 rpm, the same dosage may require 6–8 minutes for uniform distribution because the lower shear energy relative to twin-shaft mixing delays fiber separation.

    Moisture management influences dispersion. Opened fiber bags stored at relative humidity above 60% have shown surface moisture uptake that increases clumping. Fiber should not be introduced into the mixer if visible condensation is present on the packaging. Storage temperature is maintained in the range of 5–35°C to prevent package embrittlement or moisture transfer.

    Where plain concrete would fail at first crack, the function of RF4000-PVA shifts from matrix cracking to fiber bridging across the opening crack. In beam tests conducted under ASTM C1609/C1609M-24, the residual flexural strength of concrete containing 0.5 vol% RF4000-PVA is evaluated at net deflections of 1/600 and 1/150 of span. The residual strength ratio depends on matrix compressive strength; concretes in the 30–60 MPa range exhibit higher fiber-matrix bond than low-strength matrix, but may also exhibit brittle fiber rupture if the embedded length is less than 20 mm. At a dosage of 4.0 kg/m³, the fiber population is approximately 225,000 fibers/m³ based on an individual fiber mass of 0.0178 g. This fiber count reduces the average spacing between individual fibers and is a controlling variable for crack-width control. Published data for this specific configuration is limited when the beam depth is less than 100 mm, because the fiber length approaches the cross-sectional dimension and orientation becomes highly anisotropic.

    The hydrophilic PVA surface produces interfacial bond values that can exceed polypropylene by a factor of 2 to 3 in cementitious matrices, as reported in published interfacial shear test data. Because the fiber modulus is 30 GPa rather than the 210 GPa of steel, the fiber contributes less to crack-bridging stiffness at crack openings above approximately 0.5 mm. At larger crack openings, performance depends on fiber anchorage length, dosage, and matrix compactness; published data for this specific configuration is limited when the crack opening exceeds 3.0 mm.

    Comparative Response Against Steel and Polypropylene Macrofibers

    The selection of RF4000-PVA over alternative macrofibers is evaluated through differences in density, modulus, alkali resistance, and bond mechanisms. Steel hooked-end macrofibers have a density of approximately 7.85 g/cm³ and a modulus of 210 GPa, but they remain susceptible to chloride-induced corrosion in cracked or carbonated concrete and can impair pumpability at high dosage. Polypropylene macrofibers have a density of about 0.91 g/cm³ and a modulus commonly in the range of 3–10 GPa, which limits their contribution to flexural stiffness. RF4000-PVA occupies an intermediate position: lower modulus than steel but higher modulus than polypropylene, with the additional consequence of a hydrophilic surface that resists fiber withdrawal by frictional and chemical bonding.

    Representative fiber property comparison for concrete reinforcement
    PropertyRF4000-PVAHooked-end steel macrofiberPolypropylene macrofiber
    Density (g/cm³)1.307.850.91
    Tensile strength (MPa)10001000–1500400–700
    Elastic modulus (GPa)302103–10
    Elongation at break (%)71.5–410–25
    Alkali resistanceHigh; no known degradation in saturated Ca(OH)₂ at pH 12.5–13.5Corrosion risk in cracked or carbonated concreteHigh
    Matrix bond mechanismHydrophilic adhesion and friction from hydroxyl surface groupsMechanical end anchorage and friction along deformed wireHydrophobic; primarily frictional

    Representative values are compiled from manufacturer datasheets and ACI 544.1R-96. Project-specific conformance should be verified under EN 14889-2:2006 for polymer fibers and ISO 13270:2013 for steel fibers.

    When RF4000 Replaces Steel Mesh in Ground-Supported Slabs

    In ground-supported slab-on-grade construction, RF4000-PVA is introduced at dosage rates of 0.3–0.8 vol%, corresponding to approximately 3.9–10.4 kg/m³ based on the fiber density, to replace welded wire mesh as temperature-shrinkage reinforcement and to provide crack-width control under restrained contraction. The fiber is distributed through the full concrete section, whereas mesh position is often displaced during placement. RF4000-PVA does not provide the same post-crack moment capacity as continuous steel reinforcing bars at large crack openings; therefore, it is not a direct substitute for primary structural reinforcement in simply supported slabs. Joint spacing, slab thickness, and subgrade restraint should be designed according to ACI 360R-10 or local slabs-on-ground code provisions. Published data for this specific configuration is limited for slabs with joint spacing greater than 6 m, where curling and shrinkage cracking may exceed the fiber’s crack-bridging capacity.

    Plastic Shrinkage Cracking Is Controlled by Fiber Count, Not Fiber Weight

    At a dosage of 4.0 kg/m³, RF4000-PVA provides approximately 225,000 fibers/m³ because the individual fiber mass is about 0.0178 g. This count is significantly higher than that of an equal mass of hooked-end steel macrofiber with a 50 mm length and 0.75 mm diameter, which yields roughly 23,000 fibers/m³. With an isotropic orientation assumption, the nominal average center-to-center fiber spacing at this dosage is approximately 16 mm. The higher count reduces average fiber spacing. Under ASTM C1579-21, restrained panel testing with 0.5 vol% RF4000-PVA typically shows a reduction in total crack width relative to plain concrete, but the test is sensitive to placement moisture conditions; evaporation rates above 1.0 kg/m²/h still require conventional fogging, evaporation retarders, or windbreaks. Dosages below 0.3 vol% do not provide a sufficiently reduced fiber spacing to manage plastic settlement cracking in thick sections.

    Concrete workability is altered by the hydrophilic fiber surface, which increases the specific surface area of the solids phase. At 4.0 kg/m³, the added fiber surface area is approximately 18.7 m²/m³. This addition can lower slump by 10–40 mm depending on aggregate grading, cement content, and water-cement ratio. Air-entrained concrete may require an increase in air-entraining admixture of 10–20% because the fibers destabilize some air bubbles during mixing and placement. Trial batching is required to maintain specified air content under ASTM C231/C231M-22 or EN 12350-7:2019.

    Chemical compatibility is a significant difference between RF4000-PVA and steel macrofiber in repair applications. Steel fiber in calcium aluminate or calcium sulfoaluminate repair mortars can corrode if the matrix pH falls below the passivation threshold; PVA does not rely on passive film stability and is therefore used in thin-section repairs exposed to chloride or carbonation. However, PVA fiber compatibility with certain set accelerators and high-temperature curing should be verified by trial batching because accelerating salts can alter matrix-fiber bond and workability. Continuous steam-curing exposure above 70°C may require confirmation from the fiber manufacturer; published data for this specific configuration is limited for continuous exposure above 80°C.

    Dry-mix shotcrete uses RF4000-PVA as a non-corrosive reinforcement for slope stabilization and tunnel lining repair. The fiber is preblended with cement and aggregate before compressed air transport; the lower density of 1.30 g/cm³ compared with steel reduces rebound losses in overhead work. In shotcrete trials following ACI 506R-16, the fiber is typically added at 3–6 kg/m³; higher dosages may clog the nozzle when using conveying hoses with internal diameters below 50 mm. The hydrophilic fiber surface increases apparent water demand, and polycarboxylate ether superplasticizer at 0.2–0.5% by cement mass is often required to maintain a slump of 150–200 mm in wet-mix applications.

    Batch-to-batch acceptance should include measurement of fiber length, diameter, tensile strength, and alkali resistance in accordance with EN 14889-2:2006. Fiber count per kilogram can be checked by weighing a minimum of 100 g of fiber and calculating from the nominal individual fiber mass; acceptable tolerance is typically ±10% on the manufacturer’s declared fiber count. For North American projects, the supplier’s certificate of compliance should be linked to ASTM C1116/C1116M-23 and the specific lot delivered to the plant.

    Conformance test matrix for RF4000-PVA in cementitious systems
    Test propertyStandard /methodTypical declared value or criterion
    Fiber lengthEN 14889-2:2006 geometrical requirementNominal 40 mm; tolerance ±5%
    Fiber diameterEN 14889-2:2006 geometrical requirementNominal 0.66 mm
    Tensile strengthASTM D2256/D2256M-21 or ISO 2062:2009Reported nominal 1000 MPa
    Alkali resistanceEN 14889-2:2006 durability methodStrength retention after saturated Ca(OH)₂ immersion
    Concrete flexural performanceASTM C1609/C1609M-24Residual strength ratio per project specification