| Código SH | 708275 |
| Material | Álcool polivinílico (PVA) |
| Tipo De Fibra | Fibra cortada de monofilamento de alto módulo |
| Gravidade Específica | 1,30 |
| Comprimento Da Fibra | 30 milímetros |
| Diâmetro Equivalente | 0,20 mm |
| Proporção De Aspecto | 150 |
| Resistência à Tracção | 1600 MPa |
| Módulo Elástico | 40 GPa |
| Alongamento Na Ruptura | 6,0% |
| Resistência A álcalis | Excelente |
| Ponto De Fusão | 230 ° C |
| Resistência à água | Insolúvel em água com alta resistência |
Como uma fábrica acreditada da Fibra Kuraray RFD400H-PVA para reforço de concreto, aplicamos protocolos de qualidade rigorosos - cada lote passa por testes rigorosos para garantir padrões de eficácia e segurança consistentes.
| Embalagem | A fibra Kuraray RFD400H-PVA para reforço de concreto é fornecida em sacos de papel selados e resistentes à umidade. Cada saco contém 20 kg. |
| Carga de contêiner (20' FCL) | Carregamento de contêiner FCL de 20 de fibra Kuraray RFD400H-PVA em caixas seladas, paletizadas e protegidas para transporte seguro. |
| Envio | Fibra Kuraray RFD400H-PVA para navios de reforço de concreto em sacos ou caixas seladas e resistentes à umidade, paletizadas e embrulhadas em estiramento. Evite a exposição à chuva, umidade e luz solar direta. Carregue com cuidado para evitar danos às fibras. Garanta o armazenamento seco e ventilado durante o trânsito. Frete padrão ou transporte em contêineres é aceitável para este material não perigoso. |
| Armazenamento | Armazene a fibra Kuraray RFD400H-PVA em sua embalagem original fechada em uma área fria, seca e bem ventilada. Proteja da umidade, umidade, chuva e luz solar direta. Mantenha longe de fontes de calor e riscos de ignição. Não empilhe perto de paredes ou pisos onde possa ocorrer umidade. O armazenamento adequado mantém o desempenho da fibra e evita a contaminação. |
| Prazo de validade | Conservar em embalagem original fechada em condições secas. O prazo de validade é de dois anos a contar da data de fabrico. |
Competitivo Fibra Kuraray RFD400H-PVA para reforço de concreto preços que se encaixam no seu orçamento - termos flexíveis e orçamentos personalizados para cada encomenda.
Para amostras, preços ou mais informações, entre em contato conosco em +8615380400285 Ou envie para sales2@liwei-chem.com.
Responderemos a você o mais rápido possível.
Telefone: +8615380400285
E-mail: sales2@liwei-chem.com
Pagamento flexível, preço competitivo, serviço premium - Consulte-nos agora!
Kuraray RFD400H-PVA fiber is a polyvinyl alcohol fiber supplied for discrete reinforcement of cementitious matrices, including cast-in-place concrete, precast tunnel segments, sprayed concrete, repair mortars, and engineered cementitious composites. The designation identifies a specific PVA grade; the suffix “H” is commonly associated with high-tenacity polymer, while “400” is a grade or linear-density indicator. Specific nominal diameter, cut length, tensile strength, elastic modulus, and surface sizing must be taken from the current manufacturer’s technical data sheet and batch certificate. Published data for this exact configuration is limited. Class-level values for PVA fibers commonly reported in cementitious applications include density of 1.25–1.30 g/cm³, tensile strength of 880–1,600 MPa, elastic modulus of 25–42 GPa, and elongation at break of 6–10%. These values should not be used for final design without batch-specific verification under EN 14889-2:2006 or ASTM C1116/C1116M-23. The high-tenacity suffix differentiates this grade from standard PVA grades used mainly for plastic shrinkage control; comparisons between grades require consistent test methods such as ISO 527-1:2019 for filament tensile properties and ASTM C1609/C1609M-19a for concrete flexural performance.
In cementitious composites, the effectiveness of a PVA fiber depends on cut length, equivalent diameter, aspect ratio, and surface sizing. Typical PVA fiber lengths for concrete range from 4 mm to 30 mm, with equivalent diameters from 0.014 mm to 0.66 mm and aspect ratios from 50:1 to 800:1. The RFD400H configuration is normally selected according to maximum aggregate size because fibers shorter than approximately 2.5–3 times the nominal maximum aggregate size may not bridge voids effectively. Dosage is expressed as volume fraction and is commonly 0.5–2.0% by volume. For a PVA density of 1.3 g/cm³, that volume fraction corresponds to approximately 6.5–26 kg/m³, and the addition rate should be controlled by mass rather than bag count. At dosages above 1.0% by volume, a polycarboxylate ether high-range water reducer conforming to ASTM C494/C494M-19 Type F or Type G is often required to maintain slump; without such adjustment, slump measured under ASTM C143/C143M-20 may fall by more than 50 mm in a 0.45 water-to-cement ratio mix. Because PVA fiber is hydrophilic, water demand may increase at constant workability. Adding free water instead of admixture raises the effective water-to-cement ratio and reduces compressive strength, so the water-to-cement ratio should be held at or below the specified mix design value and confirmed through preconstruction trial mixing.
At dosage levels above 1.0% by volume, air content may also shift. Air content should be measured under ASTM C231/C231M-17a or EN 12350-7:2019, and air-entraining admixture dosage may require adjustment to maintain the specified air void system. The interaction between PVA fiber and air-entraining admixtures is not always linear; the preconstruction trial mix should therefore bracket the intended fiber dosage at 0.5%, 1.0%, and 1.5% by volume to establish a dosage-response curve for slump, air content, and residual flexural strength. Aggregate moisture should be measured by ASTM C70-20 or EN 1097-5:2008 and accounted for in batching so that the free water contribution does not distort the effective water-to-cement ratio.
Production-scale batching with a twin-shaft compulsory mixer or planetary counter-current mixer has shown that PVA fiber of this class is best introduced after aggregates have pre-mixed with a portion of the batch water. Early addition into a dry cement stream can cause fiber balling around mixer shafts and blades, particularly at dosage rates above 1.5% by volume. Total mixing time may need to be extended by 45–90 seconds after fiber addition; the required extension depends on mixer wear, blade clearance, and batch size. Automated fiber dispensers interlocked with the batching sequence are preferable for dosage repeatability, and a feed rate slower than approximately 20 kg/min reduces localized agglomeration in the mix. Manual addition from bags can lead to batch-to-batch variance in fiber volume fraction and should be used only when automated dosing is unavailable. In precast operations, pumpability issues are generally lower than with steel fibers, but fiber lengths above 18 mm can accumulate at reducers and small-radius elbows in concrete pumps. A pump trial before full production is recommended when the selected fiber length exceeds 18 mm or when the line includes more than two 90-degree elbows.
PVA fibers are hydrophilic and form a strong frictional and chemical bond with cement paste, while polypropylene fibers are hydrophobic and rely mainly on mechanical anchoring. This difference produces a higher interfacial bond stress for PVA, often observed as slip-hardening or fiber rupture in pullout tests, and leads to greater residual load capacity at small crack widths when measured under ASTM C1609/C1609M-19a or ISO 19044:2016. Polypropylene has a lower elastic modulus of 3.5–9 GPa and lower tensile strength, making it less effective for structural crack bridging but adequate for plastic shrinkage control. Alkali-resistant glass fiber has higher tensile strength and modulus, but it may be more susceptible to mechanical damage during mixing and has lower elongation before break. Steel fiber provides higher post-cracking flexural strength because of a modulus near 200 GPa and higher tensile strength, but it adds density and can corrode at exposed crack faces. Selection of PVA over steel is typically driven by corrosion resistance, lower density, and improved surface finish in thin sections; however, the absolute residual strength of PVA fiber-reinforced concrete is generally lower at equal volume fraction. Direct substitution requires comparative testing under ASTM C1399/C1399M-10 or EN 14651:2005+A1:2007. Published data for the RFD400H configuration specifically is limited, so project-specific flexural tests are required before changing fiber type or dosage.
| Property | PVA fiber class | Polypropylene class | Alkali-resistant glass class | Test method |
|---|---|---|---|---|
| Density | 1.25–1.30 g/cm³ | 0.90–0.91 g/cm³ | 2.68–2.78 g/cm³ | ISO 1183-1:2019 |
| Tensile strength | 880–1,600 MPa | 300–600 MPa | 1,500–3,500 MPa | ISO 527-1:2019 /ASTM D638-14 |
| Elastic modulus | 25–42 GPa | 3.5–9 GPa | 72–75 GPa | ISO 527-1:2019 /ASTM D638-14 |
| Elongation at break | 6–10% | 15–25% | 2–4% | ISO 527-1:2019 /ASTM D638-14 |
The table reports class-level published ranges and is not a substitute for the RFD400H batch certificate or project-specific qualification testing. Fiber performance in concrete is governed by both fiber properties and matrix parameters such as water-to-cement ratio, aggregate size, surface sizing, and curing regime. If the RFD400H batch certificate shows values outside these ranges, the certificate values govern the design and batching documentation.
For shotcrete, fiber length is typically limited to 12 mm or shorter to reduce rebound; wet-mix systems with high-shear dosing may accommodate lengths up to 18 mm only after pump trials confirm stable flow under EN 14487-1:2022 or an equivalent project specification. In dry-mix shotcrete, fiber dispersion is influenced by nozzle water pressure, air flow, and injection point. Nozzle air pressure above approximately 4 bar may increase fiber damage or rebound; the exact threshold should be established with preconstruction spray panels. Dosages above 1.0% by volume can increase rebound and alter accelerator demand. In-place fiber content should be verified by sprayed panel testing under EN 14488-1:2005 and EN 14488-3:2005, because the fiber volume fraction in the hardened shotcrete may differ from the nominal batch volume fraction due to rebound and overspray.
PVA fibers generally tolerate the alkaline environment of portland cement, but sustained temperatures above approximately 80°C in moist curing chambers require evaluation because polymer mechanical properties can decline at elevated temperature. Steam curing at 50–70°C for precast elements is generally compatible, but autoclave curing at 180°C and saturation pressure is outside the commonly published envelope for many PVA fibers. Published data for the RFD400H configuration specifically is limited, and the manufacturer’s technical service should approve the autoclave cycle before production use. Long-term hot-water exposure above 80°C is also not recommended without validation because hydrolytic or oxidative degradation can reduce fiber toughness over time.
Handling and storage require moisture control because PVA fiber is hygroscopic. At relative humidity above 60%, prolonged exposure can increase fiber moisture content and interfere with volumetric dispensing. Sealed bags should remain closed until dosing; fiber that has contacted water or condensation should not enter dry-mix silos because clumping can propagate into the mixer and produce fiber balls. Dosage verification on fresh concrete can use a wash-out procedure or a project-specific extraction protocol; currently no universal ISO method exists for all polymer fibers. Compliance documentation should include fiber geometry and tensile strength tested under EN 14889-2:2006 for CE marking in the European Economic Area, plus any project-required REACH or local materials declarations. The fiber is not a direct replacement for primary structural steel unless the design follows relevant fiber-reinforced concrete provisions such as ACI 544.4R-18 or fib Model Code 2010, because the lower modulus of PVA relative to steel limits load transfer at larger crack widths. Batch-to-batch variation in well-controlled PVA fiber production is often below ±5% of nominal tensile strength, but incoming material should be quarantined until a certificate of analysis is reviewed for each lot.