Fibra Nycon RF4000-PVA para reforço de concreto (130 denier)

    • Nome do produto: Fibra Nycon RF4000-PVA para reforço de concreto (130 denier)
    • Site da Factroy: Lingwu, Yinchuan, Ningxia, China
    • Consulta de preço: sales2@liwei-chem.com
    • Fabricante: Anhui Liwei Chemical Co., Limited.
    • Contacte Agora
    Especificações
    Código SH 173073
    Material Álcool polivinílico (PVA)
    Diâmetro Do Filamento Equivalente Aproximadamente 0,12 mm
    Resistência à Tracção 1.600 MPa
    Módulo De Elasticidade 30 GPa
    Alongamento Na Ruptura 6-8%
    Ponto De Fusão Aproximadamente 230 ° C
    Resistência A álcalis Excelente em ambientes cimentosos alcalinos
    Resistência Ácida Bom em ácidos leves
    Resistência Uv Bom
    Recuperação De Umidade Aproximadamente 5% em peso
    Dispersibilidade Em Concreto Excelente; superfície hidrofílica promove distribuição uniforme
    Teor De Cloreto Nenhum detectado

    Como fábrica acreditada da Fibra Nycon RF4000-PVA para reforço de concreto (130 denier), aplicamos protocolos de qualidade rigorosos - cada lote é submetido a testes rigorosos para garantir padrões de eficácia e segurança consistentes.

    Embalagem e armazenamento
    Embalagem A fibra Nycon RF4000-PVA (130 denier) é fornecida em sacos pré-pesados solúveis em água de 1 lb, 25 sacos por caixa.
    Carga de contêiner (20' FCL) Fibra Nycon RF4000-PVA, 130 denier, embalada em caixas em paletes, carregada com segurança e amarrada em um contêiner FCL de 20 pés.
    Envio A fibra Nycon RF4000-PVA é enviada como um aditivo de reforço seco e estável em sacos selados e resistentes à umidade. Nenhuma classificação de perigo especial se aplica ao transporte. Mantenha longe de fontes de ignição e armazene em uma área fria e seca. O frete terrestre padrão é típico; a entrega paletizada garante um manuseio seguro.
    Armazenamento Armazene as fibras Nycon RF4000-PVA em embalagem original selada em uma área fria, seca e bem ventilada. Proteja da umidade, chuva e luz solar direta para evitar aglomerações ou degradação. Mantenha longe de fontes de calor e materiais incompatíveis. Mantenha umidade moderada e temperaturas estáveis. Com armazenamento adequado, o produto mantém o desempenho por uma vida útil prolongada.
    Prazo de validade A vida útil é indefinida quando armazenada seca, protegida da umidade, luz solar e contaminação. Mantenha na embalagem original.
    Aplicação de Fibra Nycon RF4000-PVA para reforço de concreto (130 denier)
    Nycon RF4000 é uma fibra de monofilamento de álcool polivinil fornecida a 130 denier, correspondendo a um diâmetro nominal de filamento de aproximadamente 0,118 mm a uma densidade de filamento de 1,30 g/cm³. O material é classificado como uma microfibra de polímero de Classe I sob EN 14889-2:2006 e como um constituinte de betom reforçado com fibra sintética Tipo III sob ASTM C1116/C1116M-23. Como o denier controla o número de filamentos por unidade de massa e, portanto, a área de superfície de controle de rachaduras por metro cúbico, as proporções de adição são especificadas como massa por metro cúbico em vez de como porcentagens de peso seco do material cimentoso. Através das rotas a jusante definidas nesta seção, as doses eficazes normalmente caem entre 0,5 kg/m³ e 2,0 kg/m³, equivalente a 0,04% a 0,15% em volume a 1.300 kg/m³ densidade de polímero. Misturas contendo mais de 2,5 kg/m³ requerem reologia de pasta de engenharia e não são consideradas reforço de concreto convencional. As seguintes faixas de aplicação estão restritas à pré-fabricada arquitetônica, à produção segmental de lajes industriais, concreto pulverizado em mistura úmida, argamassa de reparação cimentina, concreto hidráulico marinho e fundição úmida, onde os padrões de teste publicados e registros de produção apoiam o uso de fibras PVA monofilamento.

    Cotação Grátis

    Preços competitivos de Fibra Nycon RF4000-PVA para reforço de concreto (130 denier) que se ajustam ao seu orçamento - termos flexíveis e orçamentos personalizados para cada encomenda.

    Para amostras, preços ou mais informações, entre em contato conosco em +8615380400285 Ou envie para sales2@liwei-chem.com.

    Responderemos a você o mais rápido possível.

    Telefone: +8615380400285

    E-mail: sales2@liwei-chem.com

    Inquérito

    Obtenha um orçamento gratuitoAnhui Liwei Chemical Co., Limited.

    Pagamento flexível, preço competitivo, serviço premium - Consulte-nos agora!

    Certificação e Conformidade
    Mais Introdução

    Nycon RF4000-PVA Fiber for Concrete Reinforcement(130 denier) is a monofilament polyvinyl alcohol fiber classified under ASTM C1116/C1116M as a Type III synthetic reinforcing fiber. The model designation RF4000-PVA identifies a 130 denier PVA monofilament supplied in 8 mm cut lengths. The 130 denier linear density is equivalent to 14.4 tex; at a fiber-specific gravity of 1.30, the equivalent filament diameter is approximately 0.12 mm. For an 8 mm cut length, this geometry produces approximately 8,500 filaments/g and 3.9 × 106 filaments/lb. The product functions as secondary crack-control reinforcement in concrete, mortar, and shotcrete. It is not a direct replacement for structural steel reinforcing bars unless project-specific structural testing establishes load-bearing performance.

    Manufacturer-published data for Nycon RF4000-PVA list tensile strength at 1,400 MPa, Young's modulus between 37 GPa and 40 GPa, elongation at break of 7%, and melting point of 225 °C. The fiber surface is hydrophilic and carries hydroxyl groups that interact with calcium silicate hydrate and portlandite through hydrogen bonding. This bond mechanism differs from the hydrophobic surface of polypropylene monofilament fibers and produces higher post-crack pullout resistance at the same fiber volume, although it can also raise water demand and influence rheology.

    ParameterPublished valueBasis or reference
    Polymer typePolyvinyl alcohol monofilamentASTM C1116/C1116M Type III synthetic fiber
    Linear density130 denier (14.4 tex)Manufacturer specification
    Equivalent filament diameter0.12 mmCalculated from linear density and density
    Cut length8 mmManufacturer specification
    Density1.30 g/cm³Manufacturer specification
    Tensile strength1,400 MPaManufacturer-reported fiber tensile value
    Young's modulus37–40 GPaManufacturer-reported fiber tensile value
    Elongation at break7%Manufacturer-reported fiber tensile value
    Melting point225 °CManufacturer specification
    Surface characterHydrophilic; hydroxyl-functionalManufacturer specification

    Why Does Linear Density Influence Dispersion and Fiber Count in Ready-Mixed Concrete?

    For a fixed cut length, filament count per unit mass scales inversely with linear density. The 130 denier RF4000-PVA filament therefore provides a higher crack-bridging fiber population per kilogram than a 400 denier macro-PVA or 600 denier polypropylene macrofiber. At a dosage of 0.25% by volume, the addition rate is approximately 5.5 lb/yd³ (3.3 kg/m³); this translates to roughly 2.1 × 107 fibers/yd³ at an 8 mm cut length. At 1.0% by volume, the fiber population rises to approximately 8.5 × 107 fibers/yd³. These populations are relevant to ASTM C1579-21 testing because crack width is governed not solely by fiber volume but by fiber spacing, bond, and filament count across the crack plane.

    The aspect ratio of the 8 mm filament at an equivalent diameter of 0.12 mm is approximately 67. Above 60, fresh-concrete rheology and pump pressure often show measurable sensitivity to fiber dosage. In a 9 m³ twin-shaft mixer, the specific failure mode for this product is filament balling when fiber is added directly to a dry cement-rich zone. Pre-blending with coarse aggregate for 1–2 minutes before cement and water addition reduces clumping. Discharge should be inspected before pumping; residual “hedgehog” agglomerates can obstruct 50 mm reducers and block concrete boom lines. No universal correction factor is available for this geometry and dosage; therefore, pumping trials using the site pump and boom length are required when fiber dosage exceeds 0.5% by volume.

    In ready-mixed and dry-shotcrete batching, the fiber is introduced after the aggregate fraction and before or during the addition of mixing water rather than being added to dry cement alone. At 0.25% by volume, the fiber mass is approximately 5.5 lb/yd³ (3.3 kg/m³); at 1.0% by volume, it is approximately 21.9 lb/yd³ (13.0 kg/m³). The lower end is commonly specified for plastic shrinkage crack control. The upper end is normally reserved for formulations requiring measurable post-crack flexural performance under ASTM C1609/C1609M, and it may require a polycarboxylate high-range water reducer to maintain a slump of 100–150 mm. The water reducer dosage is determined by trial batch under ASTM C143/C143M slump testing and ASTM C1611/C1611M slump-flow testing when the concrete is self-consolidating. Air-entraining admixture demand can change after fiber addition; the air-void system should be confirmed with ASTM C231/C231M pressure air content testing and, for hardened concrete, ASTM C457/C457M linear-traverse air-void analysis.

    In dry-mix shotcrete, the fiber is added to the dry material prior to the nozzle and mixed until the wet-mix feedstock is homogeneous. Nozzle rebound should be compared against a control batch under the same nozzle air pressure and water ring setting. In central-mix operations, a minimum post-fiber mixing time of 5 minutes at 12–18 rpm in a truck drum is recommended; shorter times may leave tangled filament clusters in the discharge. In a high-shear pan mixer, overmixing can increase air entrainment and reduce slump, so the mixing time established by the manufacturer-equipment-specific trial should not be intentionally exceeded.

    When the Product Is Evaluated Against ASTM C1609/C1609M and ASTM C1579-21

    Flexural toughness of PVA fiber-reinforced concrete is measured by ASTM C1609/C1609M using 150 × 150 × 500 mm beams loaded at third points. The standard records first-peak strength, peak strength, and residual strengths at net deflections of L/600 and L/150. In PVA fiber-reinforced cementitious matrices, the residual strength after first crack is controlled by fiber pullout and fiber rupture. Excessive interfacial bond can cause rupture rather than gradual pullout, reducing ductility. The 130 denier RF4000-PVA filament should therefore not be assumed to behave like an oil-coated PVA fiber used in engineered cementitious composites unless the supplier explicitly states such a surface treatment.

    Plastic shrinkage crack control is evaluated by ASTM C1579-21. The method applies a restrained panel with a central stress riser under controlled wind and temperature. Fiber dosage, fiber count, and matrix setting time all affect crack width and crack area. Published data for this specific configuration is limited; a trial batch using the exact cement, supplementary cementitious materials, aggregate gradation, and placement conditions is required before a crack reduction percentage can be specified. Fiber addition should not alter the specified water-cementitious materials ratio; added water to compensate for fiber-related slump loss can negate crack control benefits by increasing drying shrinkage.

    Alkali Resistance, Moisture Uptake, and Cement Matrix Interface Chemistry

    Polyvinyl alcohol filaments are stable in the alkaline pore solution of portland cement. Unlike polyester microfibers, which undergo alkaline hydrolysis at high pH, PVA does not lose strength when stored in saturated calcium hydroxide at ambient temperature. The hydroxyl groups of the polymer contribute to both water wettability and adhesion to cement hydrates. The resulting interfacial bond is typically higher than that of polypropylene, which relies on mechanical friction and a weak hydrophobic surface, and lower than deformed steel fiber anchorage, which relies on mechanical interlock and high stiffness. PVA fiber properties depend on the degree of hydrolysis of the parent polyvinyl acetate and on drawing conditions during filament manufacturing. Fibers for cement reinforcement are commonly produced from a high-hydrolysis grade, which reduces water solubility and increases crystalline ordering. The drawing process raises tensile strength to the 1,400 MPa class and modulus to 37–40 GPa.

    Because the filament is hydrophilic, storage above 60% relative humidity can increase surface moisture and cause filament-to-filament cohesion; pre-drying is required before batching if bags have been exposed to humid conditions for more than several days. The melting point of 225 °C limits the use of RF4000-PVA in structural elements with service temperatures above 200 °C or in fire-rated assemblies unless tested for the specific fire scenario. The fiber should not be exposed to strong oxidizing agents or prolonged UV storage; the cementitious matrix blocks UV after placement.

    Compatibility with polycarboxylate and naphthalene-based water reducers should be verified by trial because adsorption behavior and paste rheology differ among products. Accelerators containing calcium chloride can alter interfacial bond and should be evaluated with a representative mixture. Air-entraining admixtures may require dosage adjustments after fiber addition because the high filament population can modify air-void stability. The fiber is not a substitute for air entrainment in freeze-thaw environments; the hardened air-void system must still comply with the project specification, typically through ASTM C457/C457M.

    Unlike deformed steel fibers, RF4000-PVA does not corrode, does not rust-stain slab surfaces, and does not introduce the electrical conductivity of steel fibers. The trade-off is stiffness: steel fiber modulus is approximately 200 GPa, while PVA fiber modulus is 37–40 GPa. At equivalent volume dosage, steel fibers produce higher residual flexural strength once crack openings exceed roughly 0.5 mm; PVA fibers provide higher filament count and are more effective for controlling tight plastic shrinkage cracks with widths below 0.2 mm.

    Compared with polypropylene monofilament fibers, the PVA filament has higher density (1.30 g/cm³ vs 0.91 g/cm³), higher elastic modulus, and higher tensile strength. Polypropylene fibers are hydrophobic, lower in density, and may separate less readily from water-rich paste, but their post-crack stress transfer is lower due to poor cement adhesion. Compared with macro-PVA fibers in the 400–800 denier range, the 130 denier product yields a higher number of filaments per pound and is less visible on troweled surfaces, but it produces lower individual flexural stiffness. Compared with alkali-resistant glass fibers, PVA fibers have lower elastic modulus (37–40 GPa vs 72 GPa) and higher elongation, which may reduce matrix microcracking potential but provides greater strain capacity; AR-glass requires specific zirconia content to resist portland cement alkalinity, whereas PVA does not.

    PropertyNycon RF4000-PVA 130 denierPolypropylene monofilamentDeformed steel fiber
    Density1.30 g/cm³0.91 g/cm³7.85 g/cm³
    Tensile strength1,400 MPa300–600 MPa1,000–2,000 MPa
    Young's modulus37–40 GPa3.5–7 GPa200 GPa
    Elongation at break7%15–25%0.5–3%
    Corrosion resistanceQuasi-inert in portland cementQuasi-inert in portland cementSurface oxidation possible
    Fiber-matrix bond characterChemical adhesion via hydroxyl groupsMechanical friction; hydrophobic surfaceMechanical anchorage and friction

    In precast concrete and shotcrete applications, the 130 denier filament can be added at 0.5% by volume together with a polycarboxylate high-range water reducer to maintain pumpability. In dry-mix shotcrete, the product is introduced into the dry material before the nozzle. Rebound loss should be compared against a control batch under the same nozzle air pressure and water ring setting. In slab-on-grade construction, the fiber is dispensed onto the aggregate belt at the plant; the surface finish should be evaluated under the intended power trowel blade angle and timing because PVA filaments may remain more visible than polypropylene filaments at equal mass dosage.