Produtos

Produtos

Anhui Liwei Chemical Co., Limited.

Fibra Nycon RFD400H-PVA para reforço de concreto (360 denier)

    • Nome do produto: Fibra Nycon RFD400H-PVA para reforço de concreto (360 denier)
    • Site da Factroy: Lingwu, Yinchuan, Ningxia, China
    • Consulta de preço: sales2@liwei-chem.com
    • Fabricante: Anhui Liwei Chemical Co., Limited.
    • Contacte Agora
    Especificações
    Código SH 307996
    Material Álcool polivinílico (PVA)
    Tipo De Fibra Monofilamento
    Negação 360
    Gravidade Específica 1,30
    Resistência à Tracção Aproximadamente 1.300-1.600 MPa
    Módulo De Elasticidade Aproximadamente 30-40 GPa
    Alongamento Na Ruptura Aproximadamente 6-8%
    Temperatura De Fusão Decomposição Aproximadamente 220-230°C
    Resistência A álcalis Excelente em ambientes altamente alcalinos de concreto
    Resistência Ácida Boa resistência aos ácidos inorgânicos comuns
    Absorção De Umidade Menos de 0,5% em peso
    Cor Amarelo-branco claro

    Como fábrica acreditada da Fibra Nycon RFD400H-PVA para reforço de concreto (360 denier), aplicamos protocolos de qualidade rigorosos - cada lote é submetido a testes rigorosos para garantir padrões de eficácia e segurança consistentes.

    Embalagem e armazenamento
    Embalagem Embalado em bolsas solúveis em água, cada uma contendo 1 lb de fibra Nycon RFD400H-PVA para fácil dosagem do concreto.
    Carga de contêiner (20' FCL) A fibra Nycon RFD400H-PVA é enviada como um FCL de 20 pés, com sacos de 25 kg paletizados, presos para evitar movimentos.
    Envio A fibra Nycon RFD400H-PVA é transportada como material seco e ensacado em paletes ou em contêineres a granel. Armazene em uma área coberta e seca, longe da umidade. Nenhuma restrição especial de materiais perigosos se aplica ao transporte terrestre padrão, embora uma rotulagem adequada e carregamento seguro sejam necessários para evitar danos durante o trânsito.
    Armazenamento Armazene a fibra Nycon RFD400H-PVA em sua embalagem original fechada em uma área fria, seca e bem ventilada. Proteja da umidade, chuva e luz solar direta. Mantenha longe de chamas abertas, faíscas e calor excessivo. Mantenha temperaturas moderadas e evite empilhar paletes muito altos. Certifique-se de que a área esteja limpa e livre de contaminação potencial.
    Prazo de validade Armazene seco, longe da luz solar e umidade. A vida útil é indefinida quando mantida na embalagem original selada.
    Aplicação de Fibra Nycon RFD400H-PVA para reforço de concreto (360 denier)

    Em que dosagem um monofilamento PVA de 360 deniers aumenta a pressão da linha da bomba de shotcrete de mistura úmida além da saída confiável do bico?

    Cotação Grátis

    Preços competitivos Fibra Nycon RFD400H-PVA para reforço de concreto (360 denier) que se encaixam no seu orçamento - termos flexíveis e orçamentos personalizados para cada encomenda.

    Para amostras, preços ou mais informações, entre em contato conosco em +8615380400285 Ou envie para sales2@liwei-chem.com.

    Responderemos a você o mais rápido possível.

    Telefone: +8615380400285

    E-mail: sales2@liwei-chem.com

    Inquérito

    Obtenha um orçamento gratuitoAnhui Liwei Chemical Co., Limited.

    Pagamento flexível, preço competitivo, serviço premium - Consulte-nos agora!

    Certificação e Conformidade
    Mais Introdução

    Nycon RFD400H-PVA Fiber for Concrete Reinforcement (360 denier) is specified as a high-tenacity polyvinyl alcohol synthetic fiber for Type III fiber-reinforced concrete under ASTM C1116/C1116M. The nominal 360 denier value describes filament mass per 9,000 m; at a PVA density of 1.30 g/cm³, the calculated circular filament diameter is 0.198 mm, typically rounded to 0.20 mm. The product is used as secondary reinforcement in concrete slabs, precast panels, shotcrete, and non-structural sections to control plastic shrinkage cracking and provide post-crack residual strength. It is not intended to replace primary structural steel reinforcement unless explicitly accepted by the design engineer. Published product-specific independent data for this configuration is limited; therefore, numerical ranges in this document are typical for high-tenacity PVA monofilament reinforcement and must be confirmed against the manufacturer’s current technical data sheet and certificate of analysis.

    What Distinguishes 360-Denier PVA Filament from 200-Denier and 400-Denier Equivalents?

    Denier is not a strength grade; it is a linear mass value that fixes fiber cross-section for a given polymer density. A 360 denier filament has a linear mass of 360 g per 9,000 m. Using the PVA density of 1.30 g/cm³ and a circular cross-section assumption, the cross-sectional area is 0.0308 mm² and the diameter is 0.198 mm. A 200 denier fiber under the same assumptions has a diameter of approximately 0.148 mm, and a 400 denier fiber has a diameter of approximately 0.209 mm. At a cut length of 8 mm, the calculated aspect ratio is 40 for 360 denier, 54 for 200 denier, and 38 for 400 denier. Fiber count per kilogram at this length is approximately 3.06×10⁶ for the 360 denier product, 9.8×10⁶ for 200 denier, and 2.4×10⁶ for 400 denier. A finer denier therefore increases crack-bridging population but reduces individual filament stiffness and may raise workability demand; a coarser denier reduces fiber count but increases each filament’s tensile capacity.

    The polymer chemistry of PVA introduces hydroxyl groups along the polyvinyl alcohol backbone. These groups are hydrophilic and participate in hydrogen bonding with calcium-silicate-hydrate gel and calcium hydroxide in cement paste. Single-fiber pull-out resistance is therefore typically higher for PVA than for untreated polypropylene at equivalent aspect ratio. The 360-denier product occupies an intermediate position for bond surface area per unit mass. At equal mass addition, a 200-denier fiber exposes more total surface area, but the thicker 360-denier filament provides higher individual tensile force before rupture or slip. The selection between these deniers is a mix-design decision that should be based on trial testing under ASTM C1557 for fiber tensile properties and under ASTM C1609/C1609M for flexural toughness, not only on denier.

    The high-tenacity property is produced by a multi-step process: vinyl acetate is polymerized to polyvinyl acetate, saponified to polyvinyl alcohol, wet-spun through a spinneret, drawn to a high draw ratio, and heat-set to increase crystallinity. This process yields a fiber with a tensile modulus of 25–40 GPa, compared with melt-spun polypropylene fibers in the 3–10 GPa range. The higher modulus and hydrophilic surface contribute to lower crack widths at equivalent dosage but also increase water demand and fiber-matrix friction during mixing.

    Physical Property Benchmarks and Specification Boundaries

    Typical published ranges for high-tenacity PVA reinforcement fiber are shown in Table 1. These are not lot-specific values for RFD400H-PVA and should not be used for acceptance without the manufacturer’s batch certificate.

    PropertyHigh-tenacity PVA macrofiber (360 denier)Polypropylene macrofiberSteel hooked-end fiberRelevant test method
    Density1.29–1.31 g/cm³0.90–0.92 g/cm³7.85 g/cm³ASTM D792 /ISO 1183
    Filament diameter0.20 mm nominal0.2–1.0 mm variable0.5–1.0 mmOptical microscopy /denier calculation
    Tensile strength1,200–1,500 MPa300–600 MPa1,000–2,000 MPaASTM C1557
    Tensile modulus25–40 GPa3–10 GPa200 GPaASTM C1557
    Elongation at break6–10%15–25%3–6%ASTM C1557
    Alkali resistance in concreteHighHighCorrosion risk unless galvanized or stainlessASTM C1116/C1116M guidance
    Fiber count at 8 mm cut length3.06×10⁶ fibers/kgNot directly comparableNot directly comparableCalculated
    Water absorption tendencyHydrophilic, moisture regain approximately 4%HydrophobicNoneManufacturer data

    Table 1 is a comparative screening summary. For acceptance testing, the project specification should list exact length tolerance, denier tolerance, tensile strength, elongation, and alkali resistance requirements. Under ASTM C1116/C1116M, Type III synthetic fiber-reinforced concrete can be specified for plastic shrinkage control and post-crack performance if the fiber is evaluated using the appropriate flexural toughness method. The fiber producer’s data should state the test method and conditioning procedure used for tensile values because single-filament testing under ASTM C1557 can vary with gauge length and strain rate. The actual cross-section may not be perfectly circular; oval or crenulated cross-sections change the diameter-to-denier relationship and specific surface area. Manufacturer literature should state whether diameter is measured by optical microscopy or calculated from denier. Denier tolerance is often specified as ±5%, but this must be confirmed.

    Batching and dispersion of the 360-denier PVA fiber are more sensitive to addition sequence than to mixer type alone. In a central mixer or pan mixer, the fiber should be introduced to the moving aggregate or to the wetted concrete after 60–70% of the batch water has been added. In truck-mix operations, a pre-weighed bag should be discharged into the charging hopper over 15–20 seconds, not dropped as a single mass. At dosages up to 0.5% by volume, standard drum mixers at mixing speed can typically disperse the fiber within 3–5 minutes after the last fiber addition. At dosages above 1.0% by volume, fiber balling has been observed in low-shear equipment when the fiber is added to dry cement before water or when all bag contents are introduced at one time. Twin-shaft and high-shear pan mixers are generally more effective; a mixing time of 60–90 seconds after the last fiber bag is typical. The fiber lowers slump due to hydrophilicity and aspect ratio; a high-range water-reducing admixture conforming to ASTM C494/C494M is commonly added to maintain target slump. Air content should be rechecked after fiber addition because high surface area fibers can reduce the measured air void system. Trial batching is required when the mix contains silica fume, low water-to-cement ratio, or a viscosity-modifying admixture.

    Automatic dosing equipment must be sized for the fiber length and bag mass. At 8 mm cut length, bridging in hoppers with throat diameters below 100 mm has been observed. A vibrating chute or belt feeder is preferred. The fiber should not be added directly to cement powder or to high-range water reducer concentrate because localized polymer-cement interaction may form fiber aggregates before mixing. At addition rates above 1.5% by volume, concrete pump line pressures may increase because fibers increase plastic viscosity. Pump operators should pre-wet the line and use a pump rated for high-viscosity mixes. A placing boom with a reducer from 125 mm to 100 mm line has been used successfully with 8 mm PVA fiber at dosages up to 1.0% by volume, but line size reductions below 100 mm are not recommended without a trial. The fiber orientation in a pumped line is partially aligned along the flow direction; this promotes anisotropic post-crack behavior. Saw-cut joint spacing in slabs should follow ACI 360R guidelines and should not be extended beyond the plain concrete recommendation solely because fibers are present.

    When the Mix Design Must Satisfy Crack Control and Post-Crack Performance Requirements

    Use of RFD400H-PVA at higher addition rates is appropriate when the design specifies crack-width control, residual strength, or replacement of light-gauge welded wire mesh in slab-on-grade and pavement applications. Flexural performance is measured under ASTM C1609/C1609M and reported as residual loads at net deflections of L/600 and L/150. A round panel test under ASTM C1550 is often specified for shotcrete and tunnel linings. At fiber dosages of 0.5–1.5% by volume, residual strength is influenced by fiber aspect ratio, fiber-matrix bond, and orientation. PVA fibers at 360 denier with an 8 mm cut length have an aspect ratio of 40; increasing to 12 mm raises the aspect ratio to 60 and improves pull-out resistance but may decrease workability and increase clumping tendency.

    For plastic shrinkage crack control, slab testing under ASTM C1579 is used. Synthetic fibers at dosages of 0.3–0.9% by volume have been reported to reduce crack width and total crack area relative to plain concrete; reported values vary with evaporation rate, concrete temperature, aggregate volume, and finishing practice. The fiber’s higher tensile strength and modulus compared with polypropylene macrofiber result in lower elongation under crack-bridging stress, which can produce narrower early-age cracks. The fiber is not a substitute for proper curing, wind breaks, or fogging in severe evaporation conditions.

    Shotcrete and precast applications impose additional limitations. In wet-mix shotcrete, fiber addition at 0.5–1.5% by volume may increase pump pressure. A maximum aggregate size of 10 mm is commonly used to prevent nozzle blockages. PVA fiber has lower density than steel and usually exhibits lower rebound loss in dry-mix shotcrete, but spray pattern and air pressure must be adjusted; nozzle trials are required before full production. For precast concrete, vibration and form geometry can orient fibers along flat surfaces; this anisotropic orientation may not be captured by laboratory beam specimens molded in one direction. PVA is resistant to the high-pH environment of hydrating cement. Unlike E-glass fiber, which can lose strength in an alkaline matrix unless manufactured as alkali-resistant glass, PVA does not require a special alkali-resistant sizing for concrete use. The fiber may be used in exposure classes where steel fiber corrosion is a concern, including marine or deicing chemical exposures. However, the fiber is non-conductive but may alter the concrete pore structure at the interfacial transition zone.

    Performance attributeTest methodApplication or note
    Plastic shrinkage crackingASTM C1579Slabs, shotcrete
    Flexural toughness and residual strengthASTM C1609/C1609MSlabs on grade, pavements
    Round panel toughnessASTM C1550Shotcrete, tunnel lining
    Compressive strengthASTM C39/C39MConfirms effect of fiber addition
    SlumpASTM C143/C143MWorkability after fiber and admixture
    Air contentASTM C231/C231MAir void system after fiber
    Fiber tensile strengthASTM C1557Single-filament test
    Fiber classificationASTM C1116/C1116MType III synthetic fiber

    Acceptance testing should be performed on the same concrete mixture used in production, not on a separate laboratory mix. Sampling and testing frequency under ASTM C1116/C1116M or the project specification should include fiber length, denier, and tensile property verification for each lot. When used with air-entraining agents, the total air content measured by ASTM C231/C231M may be lower; the air void system should be verified by ASTM C457 before concluding that freeze-thaw durability is unchanged.

    Storage and handling limits are operational boundaries. PVA fiber is hydrophilic and can take up atmospheric moisture; the typical moisture regain at 65% relative humidity is approximately 4%. Bags should be kept closed and stored at relative humidity below 60% and temperatures below 40°C. Exposure to rain, standing water, or high-humidity condensation can produce surface tackiness and fiber clumps that do not disperse in a low-shear mixer. The product should not be stored in direct contact with strong oxidizing agents or concentrated acidic solutions; the polyvinyl alcohol backbone is stable in the alkaline pore solution of concrete but less resistant to strong acids and oxidizers during handling. Continuous service temperatures should be evaluated if the concrete section is expected to exceed approximately 100°C because PVA mechanical properties decline with thermal degradation. The product does not introduce corrosion risk and may be used in non-magnetic or corrosion-sensitive applications where steel fibers are excluded. It is not intended as a direct one-to-one substitute for steel fibers in all applications; engineering evaluation of post-crack flexural strength, fiber orientation, and structural redundancy is required. The manufacturer should be requested to provide a certificate of analysis showing lot-specific denier, cut length, tensile strength, elongation, and alkali resistance under the specified test methods.