Produtos

Produtos

Anhui Liwei Chemical Co., Limited.

Sinopec-SVW Q-11-fibra PVA de alto módulo de alta resistência (fibra PVA HSHM) para concreto

    • Nome do produto: Sinopec-SVW Q-11-fibra PVA de alto módulo de alta resistência (fibra PVA HSHM) para concreto
    • Site da Factroy: Lingwu, Yinchuan, Ningxia, China
    • Consulta de preço: sales2@liwei-chem.com
    • Fabricante: Anhui Liwei Chemical Co., Limited.
    • Contacte Agora
    Especificações
    Código SH 152625
    Tipo De Fibra Fibra de álcool polivinil (PVA) de alto módulo de alta resistência
    Modelo Produto Sinopec-SVW Q-11
    Uso Primário Reforço de concreto
    Material Álcool polivinílico (PVA)
    Formulário Físico Fibra de monofilamento de corte curto
    Cor Branco a amarelo claro
    Comprimento 3 mm a 20 mm (comprimentos de corte disponíveis)
    Diâmetro 12 a 15 micrômetros
    Densidade 1,29 a 1,31 g /cm³
    Resistência à Tracção 1600 MPa ou superior
    Módulo Elástico 40 GPa ou superior
    Alongamento Na Ruptura 6 a 8 por cento
    Ponto De Fusão Cerca de 230 graus Celsius
    Resistência Alcalina Alta resistência a ambientes alcalinos
    Absorção De Umidade Menos de 5%

    Como uma fábrica credenciada Sinopec-SVW Q-11-fibra PVA de alto módulo de alta resistência (fibra PVA HSHM) para concreto, aplicamos protocolos de qualidade rigorosos - cada lote passa por testes rigorosos para garantir padrões de eficácia e segurança consistentes.

    Embalagem e armazenamento
    Embalagem Fornecido em sacos de polipropileno tecido de 20 kg com forro interno, paletizado e retrátil para manuseio e armazenamento seguros.
    Carga de contêiner (20' FCL) Carga FCL de 20 "da fibra Sinopec-SVW Q-11 HSHM PVA: paletizada, embalada em bolsa tecida, protegida dentro do recipiente para transporte seguro e eficiente de fibra de concreto.
    Envio Sinopec-SVW Q-11 HSHM PVA Navios de fibra em sacos selados e à prova de umidade em paletes, protegidos da umidade e da luz solar direta. O transporte padrão de contêineres secos é adequado em todo o mundo. Evite objetos pontiagudos durante o carregamento. Mantenha longe de fontes de ignição e armazene em uma área ventilada e fria. Manuseie com cuidado para preservar a integridade da fibra.
    Armazenamento Guarde em uma área fria, seca e bem ventilada, longe da luz solar direta, calor e fontes de ignição. Mantenha na embalagem original selada para evitar absorção de umidade e contaminação. Evite a exposição prolongada a alta umidade. Mantenha a temperatura estável; sem requisitos especiais de armazenamento perigoso. Manuseie com cuidado para preservar a integridade da fibra.
    Prazo de validade A vida útil é tipicamente de 2 anos quando armazenado em condições secas e ventiladas, longe da umidade e da luz solar direta.
    Aplicação de Sinopec-SVW Q-11-fibra PVA de alto módulo de alta resistência (fibra PVA HSHM) para concreto
    Em membros de concreto dúctil onde o desempenho de flexão residual pós-fissura é usado para a dissipação de energia sísmica e redistribuição de cisalhamento, a fibra PVA de alta resistência Sinopec-SVW Q-11 de alto módulo é introduzida em 0,5-1,2 vol%, calculada no volume total de concreto. A fibra é carregada a seco em um misturador obrigatório de dois eixos após o agregado grosseiro ter sido pré-molhado com 60-70% da água de mistura e antes de adicionar a água restante e a lama cimentosa; essa sequência reduz a bola da fibra. A descarga em lote ocorre após 90-150 s de mistura úmida de alto cisalhamento, e a queda resultante é mantida entre 100-150 mm por ajuste de um redutor de água de alta gama à base de policarboxilato em vez de por adição de água. Em doses acima de 1,0 vol%, Q-11 pode aumentar o ar preso em 1-3 pontos percentuais; uma mistura despumante é necessária quando o teor de ar excede 3,0% conforme medido por ASTM C231/C231M-22. A qualificação de flexão é realizada em vigas 150×150×500 mm sob ASTM C1609/C1609M-19a, com primeiros picos e cargas residuais em deflexões líquidas de L/600 e L/150. Em feixes de acoplamento sísmico e juntas feixe-coluna, a resistência residual especificada em L/150 geralmente varia de 1,5-3,0 MPa, dependendo do conteúdo de cimento e do bloqueio agregado. O ACI 544.4R-18 reconhece a contribuição das fibras para a resistência ao cisalhamento, mas o Q-11 não é um substituto do reforço longitudinal ou transversal primário. Os dados publicados para Q-11 específicos para subassemblagens de quadro sísmico em escala completa são limitados; verificação experimental do comportamento da região da articulação é necessária antes da utilização em elementos de alta classe de ductilidade regidos por ACI 318-19 ou EN 1998-1. Os componentes terminais incluem vigas de quadro fundidas em local, vigas de ligação de fundação, paredes de cisalhamento e vigas de acoplamento em hospitais e edifícios de resposta de emergência onde a resistência residual faz parte dos critérios de aceitação.
    Cotação Grátis

    Competitivo Sinopec-SVW Q-11-fibra PVA de alto módulo de alta resistência (fibra PVA HSHM) para preços concretos que se encaixam no seu orçamento - termos flexíveis e orçamentos personalizados para cada encomenda.

    Para amostras, preços ou mais informações, entre em contato conosco em +8615380400285 Ou envie para sales2@liwei-chem.com.

    Responderemos a você o mais rápido possível.

    Telefone: +8615380400285

    E-mail: sales2@liwei-chem.com

    Inquérito

    Obtenha um orçamento gratuitoAnhui Liwei Chemical Co., Limited.

    Pagamento flexível, preço competitivo, serviço premium - Consulte-nos agora!

    Certificação e Conformidade
    Mais Introdução

    Sinopec-SVW Q-11 High Strength High Modulus PVA Fiber (HSHM PVA Fiber) is a high-orientation polyvinyl alcohol monofilament supplied in cut lengths for concrete and mortar reinforcement. The Q-11 designation covers a high-crystallinity grade with tensile properties above commodity PVA staple. The fiber is normally available in cut lengths of 6 mm, 8 mm, and 12 mm; classification under ASTM C1116/C1116M is as a Type III synthetic fiber. Evaluation against EN 14889-2:2006 places the product within the polymer-fiber specification family for concrete. In contrast to polypropylene monofilament, the surface of Q-11 is hydrophilic and stable under alkaline pore-solution conditions, supporting anchorage through polar interaction with cement hydrates instead of mechanical deformation. The product is batched into ready-mixed concrete, precast elements, and wet- or dry-process shotcrete at typical addition rates from 0.1% to 1.5% by volume. Lot-specific tensile properties should be taken from the manufacturer’s certificate of analysis, because published independent testing on the exact Q-11 configuration remains limited.

    Does the Q-11 fiber behave as a structural macrofiber or a plastic-shrinkage microreinforcement?

    Its geometry places it in the microreinforcement category. The HSHM class is commonly reported with an equivalent diameter between 14 µm and 40 µm; macrosynthetic fibers typically have equivalent diameters above 0.1 mm, so Q-11 does not meet the usual geometric definition of a structural macrofiber. For a 12 mm cut length at 40 µm diameter, the aspect ratio is approximately 300; a 6 mm cut at 14 µm diameter yields an aspect ratio above 400. The number of fibers per kilogram for a 12 mm, 40 µm filament is on the order of 5 × 10⁷; at 14 µm diameter, the count rises to approximately 4 × 10⁸. These high aspect ratios create a dense microcrack-bridging network but also increase the risk of agglomeration in low-workability concrete. In restrained plastic-shrinkage testing under ASTM C1579, HSHM PVA fiber addition rates of 0.25% to 0.50% by volume have produced crack-area reductions exceeding 70% in laboratory slabs, though published data for the Q-11 configuration is limited and aggregate grading shifts the result. Micro-mechanical estimates indicate that for a fiber tensile strength of 1,300 MPa and interfacial bond in the range 2–4 MPa, the critical transfer length is approximately 2.3–4.6 mm for a 14 µm filament and 6.5–13 mm for a 40 µm filament. The fiber does not provide the post-crack residual strength associated with hooked-end steel fiber in ASTM C1609/C1609M testing; it is not a direct structural macrofiber substitute in that sense.

    Table 1 summarises class-representative material properties for HSHM PVA fiber from which Q-11 is drawn. The values are not guaranteed lot averages; certificates of analysis govern acceptance.

    PropertyUnitTypical HSHM class rangeTest basis
    Cut lengthmm6, 8, 12supplier specification
    Equivalent diameterµm14–40optical microscopy
    Tensile strengthMPa1,100–1,500ASTM D3822
    Tensile modulusGPa35–43ASTM D3822
    Elongation at break%6–10ASTM D3822
    Densityg/cm³1.29–1.30ISO 1183-1
    Alkali resistance, strength retention after 28 d immersion in saturated Ca(OH)2 at 20 °C% of original≥95internal soak per EN 14889-2 principles

    Batching limits and high-shear mixer dispersion of PVA monofilaments

    Production-scale batching of Q-11 involves two competing constraints: enough shear to separate individual filaments and enough free-water mobility to avoid static agglomeration around mixer blades. In twin-shaft compulsory mixers, the fiber dose is introduced most uniformly after aggregate wetting and before cement. Direct dumping of the full fiber charge onto dry aggregate can create static-charged clumps at the charging cone; staggered addition over 45–60 s through a vibratory sieve is preferred. After fiber introduction, mixing time is extended by 30–60 s beyond the baseline homogenization period. For pan-type counter-current mixers, blade tip speeds of 1.5–3.0 m/s are generally sufficient; higher speeds increase filament breakage and generate fiber lint at shaft seals. Water-to-binder ratio is the principal variable controlling dispersion. At w/c below 0.32, the paste film may be too thin to separate high-aspect-ratio fibers, and additions above 0.50% by volume typically require a mid-range water reducer or pre-dispersion in water slurry. In zero-slump dry-cast production, dosages above 0.25% by volume usually require a compensatory paste-volume increase of at least 10 L/m³ to preserve compaction under external vibration. Storage in moisture-resistant bags below 70% relative humidity reduces static charge accumulation and clumping; fibers exposed above 85% RH may require pre-drying at 60 °C before dry dosing.

    Compared with hooked-end steel and polypropylene monofilament, Q-11 occupies an intermediate position in density, modulus, and interfacial bonding. The differences determine dosing strategy and long-term crack-control behaviour rather than acting as simple one-to-one substitutions.

    PropertyUnitQ-11 HSHM PVACommodity PVAPolypropylene monofilamentHooked-end steel fiber
    Tensile strengthMPa1,100–1,500700–1,000400–7001,000–2,000
    Tensile modulusGPa35–4325–353.5–8.0200–210
    Densityg/cm³1.29–1.301.25–1.300.90–0.927.85
    Elongation at break%6–108–1515–301.5–3.0
    Bonding mechanism—polar/hydrogen bond to C–S–Hpolar but lower stiffnesshydrophobic frictionalmechanical end hook and friction
    Corrosion behaviour—alkali stable, no metallic corrosionalkali stablealkali stablecorrosion possible at crack openings unless protected

    Because of the density difference, a steel-fiber dosage of 40 kg/m³ is equivalent to 0.51% by volume; the same fiber volume with Q-11 is approximately 6.6 kg/m³. Mass-only substitution from steel to PVA can produce large fiber counts and paste-demand changes unintended by the specifier.

    When Q-11 fibers replace steel fibers in slab-on-grade and precast jacket reinforcement

    Substitution is limited to crack-control functions, not primary flexural or shear reinforcement. In slab-on-grade mixtures, addition rates of 0.25% to 0.45% by volume are used for early-age random cracking and surface quality, while welded wire or structural bar remains necessary for joint load transfer. The dosage should be reduced with maximum aggregate size above 20 mm, because short fibers are less effective in bridging mortar-rich zones around coarse aggregate. For precast segment jackets, pumpability is affected above 0.50% by volume; bentonite-free mortar and a polycarboxylate water reducer are generally required to maintain slump flow between 160 mm and 220 mm. In wet-process shotcrete, fiber addition at the hopper rather than the nozzle yields more uniform distribution and lower rebound. Partial cement replacement with silica fume or metakaolin increases paste viscosity and may require reduced fiber addition at w/b ratios below 0.30. Published flexural toughness data for Q-11 under ASTM C1550 are limited; qualification panels should be shot and tested before replacing steel fibers in any structural lining or segment application.

    Alkali hydrolysis, crystallinity retention, and bond-slip characteristics under EN 14889-2

    Polyvinyl alcohol derives long-term performance in concrete from a high degree of hydrolysis, typically above 99 mol% for high-strength grades, and from a carbon–carbon backbone that resists alkaline hydrolysis. In saturated Ca(OH)2 at 20 °C for 28 d, HSHM PVA fibers of this class retain more than 95% of original tensile strength; at 60 °C, the retention value decreases, and heat-cured precast applications should be qualified by lot-specific testing. The fiber does not undergo chloride-driven metallic corrosion, but its tensile response is temperature-sensitive. Prolonged exposure above 180 °C leads to decomposition rather than melting, so Q-11 should not be specified as structural fire protection. Bond-slip behaviour is matrix-dependent. In concretes with cube compressive strength above 60 MPa when tested to EN 12390-3, pullout may become brittle and fiber rupture can occur; in lower-strength matrices, the same fiber may pull out because the matrix fails before the fiber. This behaviour contrasts with polypropylene, which slips at lower interfacial stress due to its hydrophobic surface, and with steel fibers, which mobilize mechanical anchorage. The comparison matters when plastic-shrinkage control is the performance objective, because excess bond can reduce workability without proportionally increasing post-crack toughness.

    Conformance documentation should include the certificate of analysis, cut-length distribution, lot average tensile strength, and alkali-resistance screening results. Under ASTM C1116/C1116M, Type III synthetic fiber classification does not remove the need for concrete performance testing under ASTM C1579, ASTM C1609/C1609M, or project-specific shotcrete panel requirements. Projects requiring compliance with EN 14889-2:2006 should require the manufacturer’s declaration of performance and conditioning report for each delivery lot.